Functional
Tilted Back Automated Bubble Removal Technology
12-Position Franz Cell
Integrally Molded Stirring Unit
Different rotational speeds can be achieved
Online real-time temperature monitoring
Dosing gaskets of different sizes
Take all or part of the sample
Safety Compliance
Compliant with USP, EP, and JP technical requirements.
Three levels of user rights and operation log management, in compliance with FDA 21 CFR Part 11 requirements, ensure the validity and reliability of electronic data.
Interface for easy connection to the LIMS laboratory information management system to track information and data throughout the experimental process and improve management efficiency.
Multiple alarm modes, including sampling time and temperature overload alarms, are available.
Accuracy and Reliability
With Cycle Hot dry heating module, precise temperature control can be achieved.
Tilted Back automatic air bubble removal technology ensures that no air bubbles are left during the experiment.
The one-piece PTFE stirrer is designed to form a stable fluid model and ensure the accuracy of experimental data.
Key accessories are made of Peek inert material, which has excellent corrosion resistance.
Extensive Functions
The standard 12-position Franz Cell and 12-position auto-sampling module enable efficient experiments.
Equipped with 10mL large-capacity, high-precision syringe pumps to ensure efficient and accurate experiments.
High-precision Franz Cell allows online temperature monitoring.
Different rotational speeds are available to meet the different research conditions of a wide range of experiments.
Full or partial sampling facilitates the calculation of experimental results.
The real-time replenishment function replenishes liquid simultaneously in 12 positions to minimize experimental errors.
Various sizes of dosing spacers are available for precise dosing.
The high-definition touch screen and pre-installed system software make the operation user-friendly.
Technical Specifications
12 Position Diffusion Cell Apparatus | Autosampler |
---|---|
Dissolution station: 12 positions | Sampling path: 12 ways |
Diffusion cell: improved Franz Cell | Sampling range: 0.5mL ~ 10mL |
Sampling range: 1mL ~ 10mL | Sampling accuracy: ±0.1mL |
Temperature control range: room temperature to 50℃ | Maximum sampling times: 20 times |
Drug diameter: standard 15mm(10mm, 20mm, 25mm optional) | Sampling collector size: 450mm×718mm×790mm |
Receiving liquid volume: standard 12mL (5mL, 7mL, 9mL optional) | Test tube/liquid phase vial: 240 positions |
Rotation speed range: 100rpm ~ 1000rpm, ±10% |